The thesis object of study is to compare and evaluate the results generated by the interaction between a superstructure, its foundations and the soil. This analysis was performed using a numerical model, built with the aid of finite element software. The study consists of 4 phases: In phase one, starting from the geotechnical and stratigraphic data of the soil, a first analysis was performed to evaluate the bearing capacity and the subsidence of the soil. In the second phase, on the basis of the previous geotechnical assessments, the foundations were sized and verified according to the NTC18. In these first two phases, reference data derived from an existing project were used. In the third phase, the superstructure was designed, a six-story steel / concrete tower. We proceeded with the sizing and verification of the structural elements, so we were able to extract the actions acting at the base of the structure. In the fourth and final phase, the 3 models were implemented, using the FEM software to evaluate and compare the results obtained from their soil-foundation-superstructure interactions.

L’oggetto di studio della tesi è confrontare e valutare i risultati generati dall’interazione fra una sovrastruttura, le relative fondazioni e il suolo. Questa analisi è stata eseguita tramite un modello numerico, costruito con l’ausilio di un software agli elementi finiti. Lo studio si compone di 4 fasi: Nella fase uno, partendo dai dati geotecnici e stratigrafici del terreno è stata eseguita una prima analisi per valutare la capacità portante e i cedimenti del terreno. Nella seconda fase, sulla base delle valutazioni geotecniche precedenti, si è proceduto al dimensionamento delle fondazioni e alla loro verifica secondo le NTC18. In queste prime due fasi si sono utilizzati dei dati di riferimento ricavati da un progetto esistente. Nella terza fase è stata progettata la sovrastruttura, una torre di sei piani in acciaio/calcestruzzo. Si è proceduto con il dimensionamento e la verifica degli elementi strutturali, sii sono così potuti estrarre le azioni agenti alla base della struttura. Nella quarta ed ultima fase sono stati implementati i 3 modelli, tramite l’ausilio del software FEM vengono valutati e confrontati i risultati ottenuti dalle loro interazioni suolo-fondazioni-sovrastruttura.

Interazione suolo struttura: fondazioni profonde su pali per un edificio a torre in struttura mista acciaio/calcestruzzo.

DI BARTOLO, GIANLUCA
2018/2019

Abstract

The thesis object of study is to compare and evaluate the results generated by the interaction between a superstructure, its foundations and the soil. This analysis was performed using a numerical model, built with the aid of finite element software. The study consists of 4 phases: In phase one, starting from the geotechnical and stratigraphic data of the soil, a first analysis was performed to evaluate the bearing capacity and the subsidence of the soil. In the second phase, on the basis of the previous geotechnical assessments, the foundations were sized and verified according to the NTC18. In these first two phases, reference data derived from an existing project were used. In the third phase, the superstructure was designed, a six-story steel / concrete tower. We proceeded with the sizing and verification of the structural elements, so we were able to extract the actions acting at the base of the structure. In the fourth and final phase, the 3 models were implemented, using the FEM software to evaluate and compare the results obtained from their soil-foundation-superstructure interactions.
2018
Structure soil interaction: deep foundations on pile for a tower building in a mixed steel / concrete structure.
L’oggetto di studio della tesi è confrontare e valutare i risultati generati dall’interazione fra una sovrastruttura, le relative fondazioni e il suolo. Questa analisi è stata eseguita tramite un modello numerico, costruito con l’ausilio di un software agli elementi finiti. Lo studio si compone di 4 fasi: Nella fase uno, partendo dai dati geotecnici e stratigrafici del terreno è stata eseguita una prima analisi per valutare la capacità portante e i cedimenti del terreno. Nella seconda fase, sulla base delle valutazioni geotecniche precedenti, si è proceduto al dimensionamento delle fondazioni e alla loro verifica secondo le NTC18. In queste prime due fasi si sono utilizzati dei dati di riferimento ricavati da un progetto esistente. Nella terza fase è stata progettata la sovrastruttura, una torre di sei piani in acciaio/calcestruzzo. Si è proceduto con il dimensionamento e la verifica degli elementi strutturali, sii sono così potuti estrarre le azioni agenti alla base della struttura. Nella quarta ed ultima fase sono stati implementati i 3 modelli, tramite l’ausilio del software FEM vengono valutati e confrontati i risultati ottenuti dalle loro interazioni suolo-fondazioni-sovrastruttura.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per contatti: unitesi@unipv.it