Based on the shaking table test on a sacco stone masonry façade, resorting to LNEC (Laboratόrio Nacional de Engenharia Civil, Lisbon, Portugal) tri-axial shaking table, a simplyfied code to assess the out-of-plane dynamic behaviour of a typical Portuguese unreinforced wall is presented. Besides, an experimental test on a sacco stone masonry under one sided-rocking free oscillation was carried out, in order to forecast and assess the response of the specimen through the numerical modelling. Regarding the out-of-plane shaking table tests on sacco stone masonry walls (as commonly observed in Portugal as well as in the Mediterranean area), no specifically devoted out-of-plane shaking table test on real and full scale specimens were found before LNEC tests. For this reason, and bearing in mind the vulnerability of stone masonry constructions, the dynamic out-of-plane behaviour of sacco stone masonry walls should be studied and supported by experimental evidence based on the shaking table tests. The aim of the work is to simulate the behavior of the portion of the façade collapsed during LNEC experimental test and to predict the behavior of the new specimen under one-sided free oscillations with an equivalent block approach (EBA), in order to obtain a simplified procedure to reproduce the behavior of a typical masonry façade.

Modello semplificato per la valutazione del comportamento sismico fuori-piano di una parete in muratura di granite a sacco Sulla base degli esperimenti su una facciata in muratura a ‘sacco’ in pietra svolti su tavola vibrante presso LNEC (Laboratόrio Nacional de Engenharia Civil, Lisbona, Portogallo), viene presentato un codice semplificato per la valutazione del comportamento dinamico fuori piano di una tipica tipologia di muratura portoghese. Inoltre, è stato svolto un test sperimentale su una parete in oscillazione, della stessa tipologia, così da predirne e valutarne la risposta col codice modellato. Riguardo i test su tavola vibrante di elementi in muratura a sacco in pietra, nessuno specifico esperimento è stato svolto prima degli esperimenti al LNEC. Per questa ragione, e ricordando l’alta vulnerabilità delle costruzioni di muratura in pietra, il comportamento dinamico fuori piano di questa tipologia di muratura dovrebbe essere studiato e supportato da evidenze sperimentali. Lo scopo del lavoro è quello di simulare il comportamento della porzione di facciata collassata durante gli esperimenti al LNEC e di predire il comportamento del nuovo campione tramite un blocco equivalente, in modo da ottenere una procedura semplificata per riprodurre il comportamento fuori piano di una tipica facciata portoghese in muratura.

A SIMPLIFIED MODEL TO ASSESS THE OUT-OF-PLANE SEISMIC BEHAVIOUR OF A SACCO GRANITE MASONRY WALL

MIGLIETTA, MARCO
2013/2014

Abstract

Based on the shaking table test on a sacco stone masonry façade, resorting to LNEC (Laboratόrio Nacional de Engenharia Civil, Lisbon, Portugal) tri-axial shaking table, a simplyfied code to assess the out-of-plane dynamic behaviour of a typical Portuguese unreinforced wall is presented. Besides, an experimental test on a sacco stone masonry under one sided-rocking free oscillation was carried out, in order to forecast and assess the response of the specimen through the numerical modelling. Regarding the out-of-plane shaking table tests on sacco stone masonry walls (as commonly observed in Portugal as well as in the Mediterranean area), no specifically devoted out-of-plane shaking table test on real and full scale specimens were found before LNEC tests. For this reason, and bearing in mind the vulnerability of stone masonry constructions, the dynamic out-of-plane behaviour of sacco stone masonry walls should be studied and supported by experimental evidence based on the shaking table tests. The aim of the work is to simulate the behavior of the portion of the façade collapsed during LNEC experimental test and to predict the behavior of the new specimen under one-sided free oscillations with an equivalent block approach (EBA), in order to obtain a simplified procedure to reproduce the behavior of a typical masonry façade.
2013
A SIMPLIFIED MODEL TO ASSESS THE OUT-OF-PLANE SEISMIC BEHAVIOUR OF A SACCO GRANITE MASONRY WALL
Modello semplificato per la valutazione del comportamento sismico fuori-piano di una parete in muratura di granite a sacco Sulla base degli esperimenti su una facciata in muratura a ‘sacco’ in pietra svolti su tavola vibrante presso LNEC (Laboratόrio Nacional de Engenharia Civil, Lisbona, Portogallo), viene presentato un codice semplificato per la valutazione del comportamento dinamico fuori piano di una tipica tipologia di muratura portoghese. Inoltre, è stato svolto un test sperimentale su una parete in oscillazione, della stessa tipologia, così da predirne e valutarne la risposta col codice modellato. Riguardo i test su tavola vibrante di elementi in muratura a sacco in pietra, nessuno specifico esperimento è stato svolto prima degli esperimenti al LNEC. Per questa ragione, e ricordando l’alta vulnerabilità delle costruzioni di muratura in pietra, il comportamento dinamico fuori piano di questa tipologia di muratura dovrebbe essere studiato e supportato da evidenze sperimentali. Lo scopo del lavoro è quello di simulare il comportamento della porzione di facciata collassata durante gli esperimenti al LNEC e di predire il comportamento del nuovo campione tramite un blocco equivalente, in modo da ottenere una procedura semplificata per riprodurre il comportamento fuori piano di una tipica facciata portoghese in muratura.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per maggiori informazioni e per verifiche sull'eventuale disponibilità del file scrivere a: unitesi@unipv.it.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14239/20114