Assuming the construction of a hotel in the structure of Corps B of the Valla College, the thesis compares the measures to be adopted following the Ministerial Decree of 09 April 1994 "Approval of the technical regulation of fire prevention for the construction and exercise of tourist accommodation activities- hotels" and the measures of the Fire Prevention Code. Two different approaches can be deduced from the comparison between the regulations. In the Fire Prevention Code greater importance is given to the ability to detect the fire and sound the alarm quickly. In DM 09/04/1994 the detection and alarm times of a fire can be longer and for this reason it is considered appropriate to increase the fire resistance class and adopt better performing fire control and extinguishing tools.

Ipotizzando la realizzazione di un albergo nella struttura del Corpo B del Collegio Valla, la tesi mette a confronto le misure da adottare seguendo il DM 09 Aprile 1994 "Approvazione della regola tecnica di prevenzione incendi per la costruzione e l'esercizio delle attività ricettive turistico-alberghiere" e le misure del Codice di Prevenzione Incendi. Dal confronto fra le normative si possono dedurre due approcci diversi. Nel Codice di Prevenzione Incendi è data maggior importanza alla capacità di rilevare l’incendio e di dare l’allarme in tempi rapidi. Nel DM 09/04/1994 i tempi di rilevazione e allarme di un incendio possono essere più lunghi e per questo si ritiene opportuno aumentare la classe di resistenza al fuoco e adottare strumenti di controllo ed estinzione dell’incendio più performanti.

Adeguamento antincendio di un albergo nella struttura del Collegio Valla, confronto tra il DM 09 aprile 1994 e il Codice di Prevenzione Incendi

FILIPPI, PAOLO
2018/2019

Abstract

Assuming the construction of a hotel in the structure of Corps B of the Valla College, the thesis compares the measures to be adopted following the Ministerial Decree of 09 April 1994 "Approval of the technical regulation of fire prevention for the construction and exercise of tourist accommodation activities- hotels" and the measures of the Fire Prevention Code. Two different approaches can be deduced from the comparison between the regulations. In the Fire Prevention Code greater importance is given to the ability to detect the fire and sound the alarm quickly. In DM 09/04/1994 the detection and alarm times of a fire can be longer and for this reason it is considered appropriate to increase the fire resistance class and adopt better performing fire control and extinguishing tools.
2018
Fire adjustment of a hotel in the Collegio Valla structure, comparison between the Ministerial Decree of 09 April 1994 and the Fire Prevention Code
Ipotizzando la realizzazione di un albergo nella struttura del Corpo B del Collegio Valla, la tesi mette a confronto le misure da adottare seguendo il DM 09 Aprile 1994 "Approvazione della regola tecnica di prevenzione incendi per la costruzione e l'esercizio delle attività ricettive turistico-alberghiere" e le misure del Codice di Prevenzione Incendi. Dal confronto fra le normative si possono dedurre due approcci diversi. Nel Codice di Prevenzione Incendi è data maggior importanza alla capacità di rilevare l’incendio e di dare l’allarme in tempi rapidi. Nel DM 09/04/1994 i tempi di rilevazione e allarme di un incendio possono essere più lunghi e per questo si ritiene opportuno aumentare la classe di resistenza al fuoco e adottare strumenti di controllo ed estinzione dell’incendio più performanti.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per maggiori informazioni e per verifiche sull'eventuale disponibilità del file scrivere a: unitesi@unipv.it.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14239/21338