The seismic events that stuck the Emilia region on May 2012 have highlighted the vulnerability of precast buildings, tipically one floor industrial buildings. In particular, the cladding-to-structure connections did not perform as had been expected in their design, causing the collapse of these non-structural elements. The current design practice of precast buildings is based on a frame mode, where the peripheral cladding panels enter only as masses without any stiffness. The panels are then connected to the structure with fastenings dimensioned with a local calculation on the basis of their mass for anchorage forces orthogonal to the plane of the panels. In this study were modeled two structures: in the first one the peripheral panels are modeled only as masses applied to the columns, in the second structure the panels are explicitly modeled and connected to the structure through links. Linear and non-linear analysis were performed on the two models in order to compare the results obtained and evaluate the influence of explicit panel modeling.

Gli eventi sismici che hanno colpito l'Emilia - Romagna nel maggio 2012 hanno evidenziato la vulnerabilità delle strutture prefabbricate, tipicamente capannoni industriali monopiano. In particolar modo, la risposta delle connessioni tra pannelli di tamponatura e struttura non è risultata idonea rispetto alle azioni sismiche agenti, causando il crollo di questi elementi non strutturali. L'attuale pratica di progettazione degli edifici prefabbricati, infatti, si basa su una modellazione a telaio della struttura e i pannelli perimetrali vengono modellati solo come masse, trascurando il loro contributo alla rigidezza. Sono dunque state modellate due strutture: nella prima i pannelli sono modellati come masse applicate ai pilastri, nella seconda i pannelli sono esplicitamente modellati e collegati alla struttura tramite link. Analisi lineari e non lineari sono state svolte sui due modelli al fine di confrontando i risultati ottenuti nei due modelli per poter valutare l'influenza della modellazione esplicita dei pannelli.

ANALISI LINEARE E NON LINEARE DI UN EDIFICIO PREFABBRICATO IN C.A.

VILLANO, GABRIEL
2017/2018

Abstract

The seismic events that stuck the Emilia region on May 2012 have highlighted the vulnerability of precast buildings, tipically one floor industrial buildings. In particular, the cladding-to-structure connections did not perform as had been expected in their design, causing the collapse of these non-structural elements. The current design practice of precast buildings is based on a frame mode, where the peripheral cladding panels enter only as masses without any stiffness. The panels are then connected to the structure with fastenings dimensioned with a local calculation on the basis of their mass for anchorage forces orthogonal to the plane of the panels. In this study were modeled two structures: in the first one the peripheral panels are modeled only as masses applied to the columns, in the second structure the panels are explicitly modeled and connected to the structure through links. Linear and non-linear analysis were performed on the two models in order to compare the results obtained and evaluate the influence of explicit panel modeling.
2017
LINEAR AND NON-LINEAR ANALYSIS OF RC PRECAST BUILDING
Gli eventi sismici che hanno colpito l'Emilia - Romagna nel maggio 2012 hanno evidenziato la vulnerabilità delle strutture prefabbricate, tipicamente capannoni industriali monopiano. In particolar modo, la risposta delle connessioni tra pannelli di tamponatura e struttura non è risultata idonea rispetto alle azioni sismiche agenti, causando il crollo di questi elementi non strutturali. L'attuale pratica di progettazione degli edifici prefabbricati, infatti, si basa su una modellazione a telaio della struttura e i pannelli perimetrali vengono modellati solo come masse, trascurando il loro contributo alla rigidezza. Sono dunque state modellate due strutture: nella prima i pannelli sono modellati come masse applicate ai pilastri, nella seconda i pannelli sono esplicitamente modellati e collegati alla struttura tramite link. Analisi lineari e non lineari sono state svolte sui due modelli al fine di confrontando i risultati ottenuti nei due modelli per poter valutare l'influenza della modellazione esplicita dei pannelli.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per maggiori informazioni e per verifiche sull'eventuale disponibilità del file scrivere a: unitesi@unipv.it.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14239/22177