This final thesis deals with the post-quake reconstruction topic applied to a real case. The building was the town hall of Reggiolo (RE),but after the earthquake in 2012, was declared uninhabitable. According to the project of the local authorities, the new building will house the Civil Protection headquarter and some municipal offices that could be converted in flats. Therefore, it was made an analysis of the existing layout of the town and in particular of the square where the building is located, highlighting elements of greater value and general strategies to follow. Moreover, the rising features from the new building function were taken into account and developed: useful spaces for civil protection, offices versatility, symbolic value of the building as the Civil Protection headquarter and, finally, safety in case of earthquake. The anti-seismic aspect of the structure was carried out evaluating the use of seismic isolation and comparing the response of the structure with the fixed-base solution. Finally, the heating and cooling system has been projected together with a suitable emission system.
Il seguente lavoro affronta la tematica della ricostruzione post-sisma applicata ad un caso reale. L’edificio in questione si trova a Reggiolo (RE) e ospitava il municipio del paese che, in seguito al sisma avvenuto nel 2012, è ora dichiarato inagibile. Secondo il progetto delle autorità locali il nuovo edificio dovrà ospitare il Centro Operativo Comunale della Protezione Civile e alcuni uffici Comunali che potranno essere convertiti, in un secondo momento, in residenze. E’ stata effettuata, quindi, un’analisi dell’esistente e in particolare della piazza in cui l’edificio è ubicato, indicando gli elementi di maggior pregio e le strategie generali da seguire nella progettazione. In seguito, sono stati presi in considerazione e sviluppati gli aspetti che scaturiscono dalla nuova funzione dell’edificio: spazi necessari alla protezione civile, versatilità degli ambienti adibiti ad ufficio, aspetto simbolico che l’edificio deve assumere in quanto sorto laddove giaceva un edificio gravemente danneggiato dal sisma e futuro centro della Protezione Civile comunale e infine, la sicurezza in caso di sisma. Per quanto riguarda l’aspetto antisismico della struttura si è proceduto valutando l’utilizzo di isolamento sismico e confrontando la risposta della struttura con la soluzione a base fissa. Infine, l’aspetto impiantistico è stato affrontato facendo un piccolo dimensionamento dell’impianto di raffrescamento e riscaldamento dell’edificio e proponendo un sistema di emissione adeguato all’utilizzo dell’edificio.
Ricostruire dopo il sisma : Progetto di edificio pubblico con isolamento sismico a Reggiolo
MORETTI, MATTIA
2014/2015
Abstract
This final thesis deals with the post-quake reconstruction topic applied to a real case. The building was the town hall of Reggiolo (RE),but after the earthquake in 2012, was declared uninhabitable. According to the project of the local authorities, the new building will house the Civil Protection headquarter and some municipal offices that could be converted in flats. Therefore, it was made an analysis of the existing layout of the town and in particular of the square where the building is located, highlighting elements of greater value and general strategies to follow. Moreover, the rising features from the new building function were taken into account and developed: useful spaces for civil protection, offices versatility, symbolic value of the building as the Civil Protection headquarter and, finally, safety in case of earthquake. The anti-seismic aspect of the structure was carried out evaluating the use of seismic isolation and comparing the response of the structure with the fixed-base solution. Finally, the heating and cooling system has been projected together with a suitable emission system.È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per maggiori informazioni e per verifiche sull'eventuale disponibilità del file scrivere a: unitesi@unipv.it.
https://hdl.handle.net/20.500.14239/23843