Ensuring reliability and efficiency in electrical machines, especially hydro power generators, necessitates precise assessment of insulation conditions. This thesis investigates various measurement methods to accurately evaluate insulation status, focusing specifically on the underlying mechanisms of insulation aging and the practical application of these methods. Initially, an extensive literature review was conducted to identify existing evaluation techniques and to understand insulation degradation processes. Subsequently, experimental test objects were developed to simulate the insulation properties of electrical machines, allowing controlled experimentation and assessment of selected measurement methods. The most promising techniques, identified through rigorous testing, were then applied to actual electrical machines to determine their real-world applicability and effectiveness. Through comparative analysis of experimental and real-world data, the research successfully identified the most dependable, accurate, and practical measurement method suitable for assessing insulation conditions in hydro power generators. The selected method demonstrated significant potential for enhancing maintenance practices, contributing directly to improved machine longevity and operational efficiency. Consequently, this study provides a solid foundation for future advancements in insulation evaluation techniques, facilitating more effective maintenance strategies and optimal performance of electrical machines.
Garantire l'affidabilità e l'efficienza delle macchine elettriche, in particolare dei generatori idroelettrici, richiede una valutazione precisa delle condizioni dell'isolamento. Questa tesi indaga diversi metodi di misurazione per valutare accuratamente lo stato dell'isolamento, concentrandosi in particolare sui meccanismi di invecchiamento dell'isolamento e sull'applicazione pratica di tali metodi. Inizialmente, è stata condotta un'ampia revisione della letteratura per identificare le tecniche di valutazione esistenti e comprendere i processi di degrado dell'isolamento. Successivamente, sono stati sviluppati oggetti sperimentali che simulano le proprietà isolanti delle macchine elettriche, consentendo una sperimentazione controllata e una valutazione dei metodi di misura selezionati. Le tecniche più promettenti, individuate attraverso rigorosi test, sono state poi applicate a macchine elettriche reali per determinarne l'applicabilità e l'efficacia pratica. Attraverso un'analisi comparativa dei dati sperimentali e di quelli ottenuti da applicazioni reali, la ricerca ha identificato con successo il metodo di misurazione più affidabile, accurato e pratico per la valutazione delle condizioni dell'isolamento nei generatori idroelettrici. Il metodo selezionato ha dimostrato un significativo potenziale per migliorare le pratiche di manutenzione, contribuendo direttamente all'aumento della longevità delle macchine e dell'efficienza operativa. Pertanto, questo studio fornisce una solida base per futuri sviluppi nelle tecniche di valutazione dell'isolamento, facilitando strategie di manutenzione più efficaci e prestazioni ottimali delle macchine elettriche.
INDAGINE SUI METODI PER LA VALUTAZIONE DELLO STATO DI ISOLAMENTO NELLE MACCHINE ELETTRICHE
KHANAMOOPOUR KHEDMATGOZAR, AMIRHOSSEIN
2024/2025
Abstract
Ensuring reliability and efficiency in electrical machines, especially hydro power generators, necessitates precise assessment of insulation conditions. This thesis investigates various measurement methods to accurately evaluate insulation status, focusing specifically on the underlying mechanisms of insulation aging and the practical application of these methods. Initially, an extensive literature review was conducted to identify existing evaluation techniques and to understand insulation degradation processes. Subsequently, experimental test objects were developed to simulate the insulation properties of electrical machines, allowing controlled experimentation and assessment of selected measurement methods. The most promising techniques, identified through rigorous testing, were then applied to actual electrical machines to determine their real-world applicability and effectiveness. Through comparative analysis of experimental and real-world data, the research successfully identified the most dependable, accurate, and practical measurement method suitable for assessing insulation conditions in hydro power generators. The selected method demonstrated significant potential for enhancing maintenance practices, contributing directly to improved machine longevity and operational efficiency. Consequently, this study provides a solid foundation for future advancements in insulation evaluation techniques, facilitating more effective maintenance strategies and optimal performance of electrical machines.| File | Dimensione | Formato | |
|---|---|---|---|
|
Amirhossein_Khanamoopour_Khedmatgozar_531606_pdfA.pdf
accesso aperto
Dimensione
2.98 MB
Formato
Adobe PDF
|
2.98 MB | Adobe PDF | Visualizza/Apri |
È consentito all'utente scaricare e condividere i documenti disponibili a testo pieno in UNITESI UNIPV nel rispetto della licenza Creative Commons del tipo CC BY NC ND.
Per maggiori informazioni e per verifiche sull'eventuale disponibilità del file scrivere a: unitesi@unipv.it.
https://hdl.handle.net/20.500.14239/34046